CITY GAS DISTRIBUTION (Energy that creates a better path): Instantaneous Water Heaters (Gas Geyser) Installation

Wednesday, March 24, 2021

Instantaneous Water Heaters (Gas Geyser) Installation

Model of Gas Geyser shall be of suitable brand of customer's choice but complying to prevailing guidelines and having a maximum capacity of 10 liters of water per minute and operating at normal working pressure of 21 mbar (g). The appliance shall be manufactured, tested and marked in accordance with all the requirements of IS 15558 or BS EN 26 standards.

Gas geyser should have the following safety features

Flame Failure Device                                                                                                                                            
Over-heat Protection Device
Gas & Water stability device
Oxygen depletion sensor
Incomplete combustion safety device

Geyser / water heaters can be supplied with the following types of flue

Balanced Flue:

This is where both the air for combustion and products of combustion / fumes are taken from and extracted to outside of the building. The Balanced Flue or room sealed type geyser/ water heater are much safer and are the preferred type. They can be installed on an external wall in any room of a property.

External Flue:

This is where the air for combustion is taken from inside the room and the products of combustion / fumes are discharged to outside of the building. The geyser will have a flue pipe fitted to the flue outlet socket of the geyser that will take the fumes to outside the building.

Flueless:

This is where both the air for combustion and products of combustion / fumes are taken and discharged into the room.

Gas Geysers should only be installed in areas like,

Balance flue and external flue type geysers can be installed inside kitchens, utility rooms, and passageways if adequate ventilation is available.

Flue-less type gas geyser can be installed outside the property in a balcony provided it is protected from the weather. In no case it should be installed inside bathroom / bedroom / any other passage area.

Gas Geyser should be installed at such a height that it can be switched off easily. No Gas Geyser is permitted to be concealed.

Tap off for gas geyser installation shall be taken from copper pipe work, downstream of gas meter. Separate Appliance Valve (AV) shall be provided for Gas Geyser.

Gas geysers Location:

Gas Geysers should only be installed in areas like:

Kitchens, Living rooms, Utility Rooms, Halls and Passageways if flueing and ventilation can be achieved.

Bedrooms / bed-sitting rooms provided room volume is greater than 20 cubic meters and ventilation requirements are fulfilled.

Gas Geyser should be installed at such a height that it can be switched off easily.

No Gas Geyser is permitted to be concealed.

Advantages of installing Geyser in Kitchen:

Safe, as chances of asphyxiation due to emission of fumes inside the bathroom is eliminated.

Hot water will be available in the Kitchen pipe for washing oily kitchen

 

 